Item NO. /Specifications |
S-40-5 |
S-40-12 |
S-40-15 |
S-40-24 |
DC output voltage |
5V |
12V |
15V |
24V |
Output voltage error(Note: 2) |
2% |
1% |
1% |
1% |
Rated output current |
8A |
3.5A |
2.8A |
1.8A |
Output current rage |
0-8A |
0-3.5A |
0-1.7A |
0-1.8A |
Wave and noise (Note: 3) |
75mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
Inlet stability (Note: 4) |
0.5% |
0.5% |
0.5% |
0.5% |
Load stability (Note: 5) |
1% |
0.5% |
0.5% |
0.5% |
DC output power |
40W |
42W |
42W |
43W |
Efficiency |
72%115VAC |
76%115VAC |
76%115VAC |
78%115VAC |
Adjustable range for DC voltage |
+10,-5% |
10% |
10% |
10% |
AC input voltage range |
85~264VAC 47~63Hz;
120~370VDC
|
Input current |
1.2A/115V 0.6A/230V |
AC Inrush current |
Cold-start current 30A/115V
60A/230V |
Leakage current |
<1mA/240VAC |
Overload proctection |
105%~150% Type: Foldback: current limiting
reset: auto recovery |
Over-voltage protection |
115%~135% |
High-temperature protection |
|
Temperature coefficient |
0.03%(0~50) |
Setup rise hold up time |
800ms, 50ms, 15ms/115VAC 300ms, 50ms,
60ms/230VAC |
Vibration |
10~500Hz, 2G 10min,/1 cycle, Period for
60min, Each axes |
Withstand voltage |
Input and output internal: 3KvAC, Input and
enclosure: 1.5KvAC, Output and enclosure:
0.5KvAC |
Isolation resistance |
Input and output internal: Input and
enclosure, Output and enclosure: 500VDC/100M |
Working temperature and hunmidity |
-10~+60(Refer to output derating
curve), 20%~90%RH
|
Store temperature and humidity |
-20℃~+85℃, 10%~95%RH |
Overall dimension |
1299838mm |
Weight |
0.45Kgs |
Safety standards |
UL1012 TUV EN60950
(IEC950,UL1950) |
EMC standards |
CISPR22(EN55022), IEC801-2, 3,4, IEC555-2
Verification |
|
Note:1. The testing
condition for the paramenter above is: 230VAC input, rated
load, 25 70% RH.Humidity. 2. Error.include the setting
error,line stability and load stability.(Note:5) 3. Wave
test: adopting"A12" double wire for 20MHz, and 0.1
UF&47UF capacitor short-circuit for interrupting. 4.
Inlet voltage stability test: when is over load, the lowest
voltage of inlet is up to the highest voltage. 5. Load
stability test: The load is from 0% to 100%. |