Item NO. /Specifications |
S-50-5 |
S-50-12 |
S-50-15 |
S-50-24 |
DC output voltage |
5V |
12V |
15V |
24V |
Output voltage error(Note: 2) |
2% |
1% |
1% |
1% |
Rated output current |
10A |
4.2A |
3.4A |
2.1A |
Output current rage |
0-10A |
0-4.2A |
0-3.4A |
0-2.1A |
Wave and noise (Note: 3) |
75mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
Inlet stability (Note: 4) |
0.5% |
0.5% |
0.5% |
0.5% |
Load stability (Note: 5) |
1% |
0.5% |
0.5% |
0.5% |
DC output power |
50W |
50.4W |
51W |
50.4W |
Efficiency |
71% |
78% |
78% |
82% |
Adjustable range for DC voltage |
+10,-5% |
10% |
10% |
10% |
AC input voltage range |
85~132VAC/170~264VAC selected by switch
47~63Hz;240~370VDC
|
Input current |
1.3A/115V 0.65A/230V |
AC Inrush current |
Cold-start current 18A/115V
36A/230V |
Leakage current |
<0.5mA/240VAC |
Overload proctection |
105%~150% Type: Foldback: current limiting
reset: auto recovery |
Over-voltage protection |
|
High-temperature protection |
|
Temperature coefficient |
0.03%(0~50) |
Setup rise hold up time |
200ms, 100ms, 30ms |
Vibration |
10~500Hz, 2G 10min,/1 cycle, Period for
60min, Each axes |
Withstand voltage |
Input and output internal: 1.5KvAC, Input
and enclosure: 1.5KvAC, Output and enclosure:
0.5KvAC |
Isolation resistance |
Input and output internal: Input and
enclosure, Output and enclosure: 500VDC/100M |
Working temperature and hunmidity |
-10~+60(Refer to output derating
curve), 20%~90%RH
|
Store temperature and humidity |
-20℃~+85℃, 10%~95%RH |
Overall dimension |
1599738mm |
Weight |
0.5Kgs |
Safety standards |
Meet UL 1012 reqirement (Not apply for the
mark) |
EMC standards |
Meet FCC PART15J Conduction class B
|
|
Note:1. The testing
condition for the paramenter above is: 230VAC input, rated
load, 25 70% RH.Humidity. 2. Error.include the setting
error,line stability and load stability.(Note:5) 3. Wave
test: adopting"A12" double wire for 20MHz, and 0.1
UF&47UF capacitor short-circuit for interrupting. 4.
Inlet voltage stability test: when is over load, the lowest
voltage of inlet is up to the highest voltage. 5. Load
stability test: The load is from 0% to 100%.
|