Item NO. /Specifications |
S-100-3 |
S-100-5 |
S-100-7.5 |
S-100-12 |
S-100-15 |
S-100-24 |
S-100-27 |
S-100-48 |
DC output voltage |
3V |
5V |
7.5V |
12V |
15V |
24V |
27V |
48V |
Output voltage error(Note: 2) |
2% |
2% |
1% |
1% |
1% |
1% |
1% |
1% |
Rated output current |
20A |
20A |
13.6A |
8.5A |
6.7A |
4.5A |
3.7A |
2A |
Output current rage |
0-20A |
0-20A |
0-13.6A |
0-8.5A |
0-6.7A |
0-4.5A |
0-3.7A |
0-2A |
Wave and noise (Note: 3) |
75mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
Inlet stability (Note: 4) |
0.5% |
0.5% |
0.5% |
0.3% |
0.3% |
0.2% |
0.2% |
0.2% |
Load stability (Note: 5) |
0.5% |
0.5% |
0.5% |
0.3% |
0.3% |
0.2% |
0.2% |
0.2% |
DC output power |
60W |
100W |
102W |
102W |
100.5W |
108W |
99.9W |
96W |
Efficiency |
70% |
78% |
80% |
81% |
81% |
84% |
84% |
84% |
Adjustable range for DC voltage |
2.85-3.3V |
4.75-5.5V |
6.75-8.25V |
10.8-13.2V |
13.5-16.5V |
21.6-26.4V |
26-32V |
43.2-52.8V |
AC input voltage range |
85~132VAC/180~264VAC selected by switch
47~63Hz; 240~370VDC |
Input current |
2.4A/115V 1.2A/230V |
AC Inrush current |
Cold-start current 30A/115V
60A/230V |
Leakage current |
<1mA/240VAC |
Overload
proctection
|
105~150%
|
105~150% |
150~200% |
105~150% |
105~150% |
105~150% |
105~150% |
105~150% |
Type: Output shutdown Reset: Recycle AC
ON/OFF |
Over-voltage protection |
|
High-temperature protection |
|
Temperature coefficient |
0.03%/(0~50) |
Setup rise hold up time |
200ms, 50ms, 20ms |
Vibration |
10~500Hz, 2G 10min,/1 cycle, Period for
60min, Each axes |
Withstand voltage |
Input and output internal: 1.5KvAC, Input
and enclosure: 1.5KvAC, Output and enclosure:
0.5KvAC |
Isolation resistance |
Input and output internal: Input and
enclosure, Output and enclosure: 500VDC/100M |
Working temperature and hunmidity |
-10~+60(Refer to output derating
curve), 20%~90%RH
|
Store temperature and humidity |
-20℃~+85℃, 10%~95%RH |
Overall dimension |
1999838mm |
Weight |
0.65Kgs |
Safety standards |
Meet UL 1012 requirement (Not apply for
the mark) |
EMC standards |
Meet FCC PART15J Conduction class
B |
|
Note:1. The testing
condition for the paramenter above is: 230VAC input, rated
load, 25 70% RH.Humidity. 2. Error.include the setting
error,line stability and load stability.(Note:5) 3. Wave
test: adopting"A12" double wire for 20MHz, and 0.1
UF&47UF capacitor short-circuit for interrupting. 4.
Inlet voltage stability test: when is over load, the lowest
voltage of inlet is up to the highest voltage. 5. Load
stability test: The load is from 0% to 100%.
|